Wireless Frac/Production Monitoring System Specifications

Gauge Housing

4.5 inch pipe
OD: 5.95 inches
ID: 3.80 inches
Length: 62.38 inches


5.5 inch pipe

OD: 7.0 inches

ID: 4.775 inches

Length: 41 inches


Pressure
Sensor: Sapphire
Standard Ranges: 1,500 to 15,000 psi
Maximum Overpressure: 50% Full Scale
Accuracy: 0.1% Full Scale
Long Term Stability: 0.1% Full Scale
Drift: < 3 psi / year
Resolution: 0.025 % Full Scale
Response Time: Instantaneous

Temperature
Standard Rating: 125 °C
Accuracy: ± 1.0 °C
Resolution: 0.01% Full Scale


Power Source: AC or solar

Data Acquisition
Record Contents: Time, Pressure, Temperature

Sensors: Tubing and/or Annulus